SUP-P300 Single crystal silicon pressure transmitter

#208

Single crystal siliconPressure transmitterSUP-P300

Product Highlights

The central sensing unit uses high-precision silicon technology
Patented double overload protection diaphragm design, unidirectional overpressure up to 40MPa.
The upper and lower ranges of the range can be arbitrarily adjusted to have a wider adaptability, and the range code with the lowest possible range is selected to optimize the performance characteristics.
Multi-parameter output application is optional.
EMC meets the latest national standards.

SUP-P300 Single crystal silicon pressure transmitter

SUP-P300 monocrystal silicon pressure transmitter is used to measure liquid, gas or steam level, density, pressure, and then convert it to 4-20mA HART current signal output, and can also communicate with BST9900, HART375 or BST Modem for parameter setting and process control.

Specifications
Model number
SUP-P3000
Power supply
24V
Measuring medium
Air, water, oil and other non-corrosive media for stainless steel and fluorine rubber
Shell protection
IP67
Compensating temperature
- 10 ~ 70 ℃
Long-term stability
Plus or minus 0.1% FS / 3 y
Natural frequency
5KHZ~650kHz
Overload pressure
150%F.S
Pressure type
Gauge pressure, absolute pressure
Measuring range
0 ~ 0.6 kPa... 60MPa (gauge pressure)
Zero temperature drift
± (0.1+0.15TD) %F.S
Comprehensive accuracy
Level 0.075/0.1 Optional
Operating temperature
- 40 ~ 85 ℃
Process connection
Threaded connection
Medium temperature
- 40 ~ 100 ℃